SOLUTIONS

2V Long Life Deep Cycle Batteries

2V Storage Batteries.jpg

The Power of Long Life - Really Long!
The DFM 2V series is a general-purpose battery with a design life of over 18 years in float service. With heavy-duty grids, thicker plates, special additives and updated AGM valve-regulated technology, the DFM 2V battery delivers consistent performance and long service life. Its new grid design effectively reduces internal resistance, providing higher specific energy density and excellent high-rate discharge characteristics.


The GFM 2V series builds on the DFM 2V platform with silica-gel electrolyte. The immobilized electrolyte eliminates acid stratification, improves deep-discharge recovery and keeps performance stable in high-temperature environments - ideal for demanding energy storage applications.

SPECIFICATIONS

2V DFM AGM RangeDFM AGM long life specification table2V GFM GEL RangeGFM GEL long life specification table
2V DFM AGM RangeTech DrawingFAQs
Serial No.Battery Model No.VoltageCapacityDimension (mm±2)WeightTerminal
(V)Ah/10hrLWHTHKg±3%TypePosition
1DFM2-200220017211133036513F7A
2DFM2-300230017215033036518.5F7G
3DFM2-400240021117533036526.2F7H
4DFM2-500250024117533036532F7H
5DFM2-600260030117533036538F7H
6DFM2-750275041017533036546F7J
7DFM2-800280041017533036551.5F7J
8DFM2-10002100047517533036562F7J
9DFM2-12002120047517533036568.5F7J
10DFM2-15002150040135034237896.6F7K
11DFM2-200022000490350342378130F7L
12DFM2-300023000712353340382192F7L

Note:

1. In the Dimension columns: L = Length, W = Width, H = Height, TH = Total Height.

2. Due to the wide range of battery models, if the battery model you are interested in is not shown in the specification chart, please contact us.

3. The specifications are subject to update without notification for reasons of improvement.

Terminal Type Drawing: F1-F20

Technical drawing of VRLA battery terminal types F1 to F20

Terminal Position (Polarity): A-L

Terminal position and polarity diagrams of VRLA batteries with layouts A to L

Frequently Asked Questions

What applications are 2V long life batteries designed for?

2V long life batteries are engineered for telecom base stations, UPS systems, solar and wind energy storage and other critical installations that require more than a decade of reliable standby power.

Why do 2V cells last longer than 12V monobloc batteries?

A 2V cell is an independent single-cell unit with thicker plates, more active material and a larger electrolyte reserve, so it ages more evenly across the string and delivers a longer float and cycle life than multi-cell 12V blocks.

What is the difference between the 10hr and 20hr capacity rates?

Capacity depends on discharge time. A 10hr rating draws more current than a 20hr rating, so the same battery shows fewer Ah at 10hr. Always size the system with the rate that matches the actual discharge profile.

What should be considered when connecting 2V cells in series?

Use cells of the same model, capacity and age in one string, keep cable resistance equal between cells, and check string voltage and individual cell voltages periodically to prevent imbalance from shortening service life.

How long is the design float life of these batteries?

Under proper float charging at 20-25 °C with a quality charger, 2V long life AGM and GEL batteries are typically designed for 15-20 years of standby service, depending on ambient temperature and cycling depth.

2V GFM GEL RangeTech DrawingFAQs
Serial No.Battery Model No.VoltageCapacityDimension (mm±2)WeightTerminal
(V)Ah/10hrLWHTHKg±3%TypePosition
1GFM2-200220017211133036513.5F7A
2GFM2-300230017215033036519F7G
3GFM2-400240021117533036527F7H
4GFM2-500250024117533036532.4F7H
5GFM2-600260030117533036538.5F7H
6GFM2-750275041017533036546F7J
7GFM2-800280041017533036552F7J
8GFM2-10002100047517533036562.5F7J
9GFM2-12002120047517533036569.5F7J
10GFM2-15002150040135034237898F7K
11GFM2-200022000490350342378132F7L
12GFM2-300023000712353340382194F7L

Note:

1. In the Dimension columns: L = Length, W = Width, H = Height, TH = Total Height.

2. Due to the wide range of battery models, if the battery model you are interested in is not shown in the specification chart, please contact us.

3. The specifications are subject to update without notification for reasons of improvement.

Terminal Type Drawing: F1-F20

Technical drawing of VRLA battery terminal types F1 to F20

Terminal Position (Polarity): A-L

Terminal position and polarity diagrams of VRLA batteries with layouts A to L

Frequently Asked Questions

How do I choose between GEL and AGM for long life applications?

Choose AGM for higher charge acceptance and lower internal resistance, and GEL for hot climates, deep daily cycling and long-duration discharge, where the gelled electrolyte resists drying out and acid stratification.

Why are GEL batteries well suited to hot climates and deep discharge?

The thixotropic gel immobilizes the acid completely, which minimizes water loss and drying at high temperatures and tolerates repeated deep discharges better than flooded designs.

What charging voltage should 2V long life batteries use?

For cyclic use charge at about 2.40-2.45 V per cell at 25 °C and for float use 2.25-2.30 V per cell, with temperature compensation; always follow the datasheet window for the specific range.

How do I size batteries for a solar energy storage system?

Calculate daily energy consumption in Wh, divide by system voltage and inverter efficiency to get Ah per day, multiply by the days of autonomy needed, and apply a depth-of-discharge factor, typically 50%, to determine total capacity.

RELATED BATTERY RANGES

FM Small UPS Battery SeriesAGM VRLA batteries for small UPS, emergency lighting and security.12V Deep-Cycle Battery SeriesDeep-cycle 12V SLA batteries for solar, RV and mobility cyclic duty.12V Front Terminal SeriesFront-terminal 12V batteries designed for narrow telecom cabinets.2V OPzV SeriesTubular gel 2V OPzV batteries for long life and deep cycling.2V OPzS SeriesFlooded tubular 2V OPzS batteries for high-capacity standby systems.

CONTACT US

If you don't find the desired battery size, need customized OEM/ODM power solutions, or have any special requirement, please contact us.